{"id":2653,"date":"2024-12-11T12:55:33","date_gmt":"2024-12-11T12:55:33","guid":{"rendered":"https:\/\/departamento.us.es\/dfisap1\/?page_id=2653"},"modified":"2026-11-14T09:40:45","modified_gmt":"2026-11-14T08:40:45","slug":"laboratorios-de-investigacion","status":"publish","type":"page","link":"https:\/\/departamento.us.es\/dfisap1\/investigacion\/laboratorios-de-investigacion\/","title":{"rendered":"Laboratorios de investigaci\u00f3n"},"content":{"rendered":"\n<h4 class=\"wp-block-heading\">Centro Andaluc\u00eda Tech. Escuela Polit\u00e9cnica Superior &#8211; CATEPS<\/h4>\n\n\n\n<div class=\"wp-block-group has-border-color is-layout-flow wp-block-group-is-layout-flow\" style=\"border-color:#eeeeee;border-style:solid;border-width:1px;padding-top:15px;padding-right:15px;padding-bottom:15px;padding-left:15px\">\n\n<div class=\"wp-block-group has-text-color has-background is-layout-flow wp-block-group-is-layout-flow\" style=\"color:#ffffff;background-color:#0b00e6;padding-top:15px;padding-right:15px;padding-bottom:15px;padding-left:15px\">\n\n<h6 class=\"wp-block-heading has-text-color\" style=\"color:#ffffff\">L1-I-FA: Laboratorio de f\u00edsica nuclear aplicada (Responsable: Francisco Jos\u00e9 Ager V\u00e1zquez)<\/h6>\n\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Equipo de fluorescencia de rayos X, X-Panda:<\/strong> tubo de rayos X Amptek Mini-X, \u00e1nodo W, 40 kV, 0.2 mA. Detector SDD Amptek X-123. Sistema automatizado de posicionamiento OWIS.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><br\/><strong>Equipo de fluorescencia de rayos X:<\/strong> tubo de rayos X Amptek Mini-X, \u00e1nodo W, 40 kV, 0.2 mA. Detector SDD Amptek X-123. Sistema de posicionamiento microm\u00e9trico manual.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><br\/><strong>Equipo de an\u00e1lisis de microfluorescencia de rayos X:<\/strong> tubo ifG\/IMOXS, \u00e1nodo W, 50 kV, 0.6 mA, lentes policapilares (50 \u00b5m), detector Amptek Super-SDD-X123. Posicionamiento automatizado de 3 ejes STANDA.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><br\/><strong>Equipo de an\u00e1lisis de microfluorescencia confocal de rayos X, \u03bcXRF-CONCHA:<\/strong> tubo de rayos X ifG\/IMOXS, \u00e1nodo de Rh, 50 kV, 0.6 mA, lentes policapilares (20 \u00b5m), detector Amptek Super-SDD-X123. Sistema automatizado de posicionamiento OWIS.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><br\/><strong>Equipo de transmisi\u00f3n de rayos gamma:<\/strong> fuentes 241Am, 57Co, 133Ba. Blindaje Pb. Detector Amptek X-123CdTe. Sistema automatizado de cambio de muestras.<\/p>\n\n<\/div>\n\n\n\n<div class=\"wp-block-group has-border-color is-layout-flow wp-block-group-is-layout-flow\" style=\"border-color:#eeeeee;border-style:solid;border-width:1px;padding-top:15px;padding-right:15px;padding-bottom:15px;padding-left:15px\">\n\n<div class=\"wp-block-group has-text-color has-background is-layout-flow wp-block-group-is-layout-flow\" style=\"color:#ffffff;background-color:#00ad00;padding-top:15px;padding-right:15px;padding-bottom:15px;padding-left:15px\">\n\n<h6 class=\"wp-block-heading has-text-color\" style=\"color:#ffffff\">L2-I-FA: Laboratorio de superficies y materiales (Responsables: Ram\u00f3n Escobar Galindo y Bertrand Lacroix)<\/h6>\n\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-794e3cfa wp-block-columns-is-layout-flex\">\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\">\n\n<p class=\"wp-block-paragraph\"><strong>Equipo PVD (Physical Vapor Deposition) tipo \u201cmini batch DC-sputtering coater\u201d<\/strong> para realizar recubrimientos funcionales sobre geometr\u00edas complejas con sistema de rotaci\u00f3n planetario en alto vac\u00edo.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Espectr\u00f3metro GDOES (Glow Discharge Emission Spectrometry)<\/strong> para el an\u00e1lisis elemental cualitativo y cuantitativo de materiales de manera r\u00e1pida y con alta resoluci\u00f3n en profundidad.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Horno de mufla (Hobersal) para tratamientos t\u00e9rmicos<\/strong> de materiales hasta temperaturas superiores a 1000\u00a0\u00b0C y experimentos de ciclado con rampas de calentamiento\/enfriamientos controlados.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Tensi\u00f3metro \u00f3ptico (Biolin Theta Flex)<\/strong> para medidas de mojado superficial est\u00e1ticas y din\u00e1micas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Sistema de iluminaci\u00f3n ultravioleta (UVA y UVB)<\/strong> para tratamientos de foto-activaci\u00f3n de materiales.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Microscopio \u00f3ptico<\/strong> para la observaci\u00f3n de muestras.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Equipamiento general de laboratorio<\/strong> (campana de extracci\u00f3n, desecador, ba\u00f1o de ultrasonidos, etc.).<\/p>\n\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\">\n\n<figure class=\"wp-block-gallery has-nested-images columns-2 is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"316\" height=\"318\" data-id=\"2810\" src=\"https:\/\/departamento.us.es\/dfisap1\/wp-content\/uploads\/2025\/01\/Imagen12.png\" alt=\"\" class=\"wp-image-2810\"\/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"270\" height=\"309\" data-id=\"2811\" src=\"https:\/\/departamento.us.es\/dfisap1\/wp-content\/uploads\/2025\/01\/Imagen3.jpg\" alt=\"\" class=\"wp-image-2811\"\/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" data-id=\"2842\" src=\"https:\/\/departamento.us.es\/dfisap1\/wp-content\/uploads\/2025\/02\/foto-tensiometro2.jpg\" alt=\"\" class=\"wp-image-2842\" srcset=\"https:\/\/departamento.us.es\/dfisap1\/wp-content\/uploads\/2025\/02\/foto-tensiometro2.jpg 1024w, https:\/\/departamento.us.es\/dfisap1\/wp-content\/uploads\/2025\/02\/foto-tensiometro2-768x576.jpg 768w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1055\" data-id=\"2843\" src=\"https:\/\/departamento.us.es\/dfisap1\/wp-content\/uploads\/2025\/02\/foto-horno-recortado.jpg\" alt=\"\" class=\"wp-image-2843\" srcset=\"https:\/\/departamento.us.es\/dfisap1\/wp-content\/uploads\/2025\/02\/foto-horno-recortado.jpg 1024w, https:\/\/departamento.us.es\/dfisap1\/wp-content\/uploads\/2025\/02\/foto-horno-recortado-768x791.jpg 768w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/figure>\n\n<\/div>\n\n<\/div>\n\n<\/div>\n\n\n\n<div class=\"wp-block-group has-border-color is-layout-flow wp-block-group-is-layout-flow\" style=\"border-color:#eeeeee;border-style:solid;border-width:1px;padding-top:15px;padding-right:15px;padding-bottom:15px;padding-left:15px\">\n\n<div class=\"wp-block-group has-text-color has-background is-layout-flow wp-block-group-is-layout-flow\" style=\"color:#ffffff;background-color:#ff0000;padding-top:15px;padding-right:15px;padding-bottom:15px;padding-left:15px\">\n\n<h6 class=\"wp-block-heading has-text-color\" style=\"color:#ffffff\">L3-I-FA: Laboratorio de preparaci\u00f3n de muestras para AMS (Responsable: Jos\u00e9 Mar\u00eda L\u00f3pez Guti\u00e9rrez)<\/h6>\n\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Horno microondas<\/strong> para digesti\u00f3n \u00e1cida y b\u00e1sica de materiales.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Horno mufla<\/strong> para combusti\u00f3n.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Equipo de destilaci\u00f3n<\/strong> para producci\u00f3n de agua ultrapura.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Equipo de prensado<\/strong> de muestras Ionplus.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Equipamiento general de laboratorio<\/strong> (campana de extracci\u00f3n, centr\u00edfuga, ba\u00f1o ultrasonidos, etc.).<\/p>\n\n<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>Centro Andaluc\u00eda Tech. Escuela Polit\u00e9cnica Superior &#8211; CATEPS L1-I-FA: Laboratorio de f\u00edsica nuclear aplicada (Responsable: Francisco Jos\u00e9 Ager V\u00e1zquez) Equipo de fluorescencia de rayos X, X-Panda: tubo de rayos X Amptek Mini-X, \u00e1nodo W, 40 kV, 0.2 mA. Detector SDD Amptek X-123. Sistema automatizado de posicionamiento OWIS. Equipo de fluorescencia de rayos X: tubo de [&hellip;]<\/p>\n","protected":false},"author":9,"featured_media":0,"parent":2581,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-2653","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/departamento.us.es\/dfisap1\/wp-json\/wp\/v2\/pages\/2653","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/departamento.us.es\/dfisap1\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/departamento.us.es\/dfisap1\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/departamento.us.es\/dfisap1\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/departamento.us.es\/dfisap1\/wp-json\/wp\/v2\/comments?post=2653"}],"version-history":[{"count":0,"href":"https:\/\/departamento.us.es\/dfisap1\/wp-json\/wp\/v2\/pages\/2653\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/departamento.us.es\/dfisap1\/wp-json\/wp\/v2\/pages\/2581"}],"wp:attachment":[{"href":"https:\/\/departamento.us.es\/dfisap1\/wp-json\/wp\/v2\/media?parent=2653"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}